China Professional Oac4000 High Quality Cheap Medical Oilless Portable 25lpm Silent Oil Free Air Compressor with Best Sales

Product Description

OAC4000 High Quality Cheap Medical Oilless Portable 25LPM Silent Oil Free Air Compressor

Features:

1. Integrated with American GAST/THOMAS oil-free pump, multiple CHINAMFG pneumatic components such as Japanese SMC& UK NORGREN,resulting in further savings on operating and maintenance costs.
2. Equipped with ORIENTAL MOTOR cooling fan from Japan. The professional thermal design can ensure properly continuous working and extend the service life of the pump.
3. Widely matched with different ventilators , CPAPs.
4. Widely used in clinic,NICU etc.
5. No oil.
6. No water.
7. Low Noise.

OAC4000 OAC3000
OAC5000 OAC3000

Technical Parameter:

Model OAC2000 OAC3000 OAC4000 OAC5000
Output pressure 0.25-0.4MPa 0.25-0.4MPa 0.25-0.4MPa 0.018MPa
Continuous flow 90LPM 40LPM 25LPM 10LPM
Peak flow >180L PM >120L PM >60LPM >30LPM
Noise ≤55dB(A) ≤55dB(A) ≤55dB(A)  
Power source AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz
Power 750VA 500VA 250VA 30VA
Thermal protection 120°C 120°C 120°C /
Pressure display Pressure gauge Pressure gauge Pressure gauge /

Our Factory

Certificates

Our Team
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Kind: Suction Machine
Certification: CE, ISO13485
Group: Adult
LCD Display: Without LCD Display
Power Supply: 220V±10% 5ohz±2%
Air Pumping Efficiency: ≥18L/Min
Samples:
US$ 200/Piece
1 Piece(Min.Order)

|
Request Sample

Customization:
Available

|

air compressor

Can Water-Lubricated Air Compressors Be Used in Cold Climates?

Water-lubricated air compressors can be used in cold climates, but there are certain considerations and precautions to keep in mind. Here’s a detailed explanation of using water-lubricated air compressors in cold climates:

Freezing of Water:

  • Potential for Freezing: In cold climates, the water used for lubrication in water-lubricated compressors can freeze, which can cause operational issues and damage to the equipment. Freezing can occur in the water supply lines, lubrication system, or water jackets if the temperature drops below the freezing point of water.
  • Water Temperature: It is important to ensure that the water temperature remains above freezing throughout the compressor system. This can be achieved by using insulation, heat tracing, or heaters to maintain adequate water temperature. Monitoring the water temperature and implementing appropriate heating measures are crucial to prevent freezing-related problems.

Protection and Insulation:

  • Protecting External Components: External components of water-lubricated compressors, such as valves, fittings, and pipes, may be exposed to cold temperatures. Insulating these components can help prevent freezing and ensure their proper functioning. Insulation materials, such as foam wraps or heat tapes, can be used to provide thermal protection.
  • Water Supply Lines: Water supply lines that feed the compressor should be properly insulated and protected from freezing temperatures. Insulation can help maintain the water temperature and prevent freezing within the supply lines. Additionally, measures such as burying the supply lines below the frost line or using heat tracing cables can offer further protection against freezing.

Alternative Lubrication Methods:

  • Oil-Lubricated Compressors: In extremely cold climates, where freezing is a significant concern, using oil-lubricated compressors instead of water-lubricated ones may be a more practical option. Oil-based lubrication systems are less prone to freezing and can provide reliable operation in colder temperatures. However, it is important to consider the specific requirements and limitations of oil-lubricated compressors for the intended application.

Manufacturer Recommendations:

  • Consulting the Manufacturer: It is crucial to consult the manufacturer’s guidelines and recommendations regarding the use of water-lubricated compressors in cold climates. Manufacturers may provide specific instructions, modifications, or alternative solutions to ensure the safe and efficient operation of their equipment under cold weather conditions.

By implementing proper insulation, heating measures, and following the manufacturer’s guidance, water-lubricated air compressors can be used effectively in cold climates. It is important to assess the specific requirements of the application and consider the potential challenges associated with freezing temperatures to ensure the reliable and safe operation of the water-lubricated compressor system.

air compressor

Are There Regulations Governing the Use of Water-Lubricated Air Compressors?

When it comes to the use of water-lubricated air compressors, there are several regulations and standards that govern their operation and ensure compliance with safety, environmental, and performance requirements. Here’s a detailed explanation of the regulations related to water-lubricated air compressors:

1. Occupational Safety and Health Administration (OSHA) Regulations:

OSHA is a regulatory agency in the United States that sets and enforces workplace safety and health standards. While OSHA does not have specific regulations solely dedicated to water-lubricated air compressors, they have general regulations that apply to all types of air compressors. These regulations include requirements for safe operation, maintenance, and guarding of equipment to protect workers from hazards such as electrical shocks, mechanical injuries, and exposure to hazardous substances.

2. Environmental Protection Agency (EPA) Regulations:

The EPA is responsible for implementing and enforcing environmental regulations in the United States. Although there are no specific regulations for water-lubricated air compressors, the EPA has regulations that govern the discharge of water and other substances into the environment. If the water-lubricated compressor system involves the use of cooling water or generates wastewater, it may be subject to regulations related to water pollution control, water treatment, and proper disposal of wastewater.

3. International Organization for Standardization (ISO) Standards:

The ISO develops international standards that provide guidelines and requirements for various industries and technologies. ISO 8573 is a standard that addresses the quality of compressed air used in different applications. This standard sets limits and specifications for various contaminants in compressed air, including water content. Water-lubricated air compressors need to comply with the requirements of ISO 8573 to ensure the produced compressed air meets the desired quality standards.

4. Manufacturer Guidelines and Recommendations:

In addition to regulatory requirements, it is essential to follow the guidelines and recommendations provided by the manufacturers of water-lubricated air compressors. Manufacturers typically provide instructions for installation, operation, maintenance, and safety precautions specific to their equipment. Adhering to these guidelines is crucial to ensure the safe and proper functioning of the equipment and to maintain warranty coverage.

It’s important to note that the specific regulations and standards governing water-lubricated air compressors may vary depending on the country or region. Therefore, it is advisable to consult the relevant regulatory agencies, industry organizations, and local authorities to ensure compliance with applicable regulations and standards in a particular jurisdiction.

By complying with the relevant regulations, standards, and manufacturer guidelines, users of water-lubricated air compressors can ensure the safe and efficient operation of their equipment while minimizing any potential environmental impacts.

air compressor

How does a water lubrication system work in air compressors?

A water lubrication system in air compressors is designed to provide lubrication and cooling to the internal components of the compressor using water as the lubricant. This system offers an alternative to traditional oil lubrication systems and has specific advantages in certain applications. Here’s a detailed explanation of how a water lubrication system works in air compressors:

1. Water Injection:

In a water lubrication system, a controlled amount of water is injected into the compression chamber of the air compressor. This can be achieved through various methods, such as direct injection or atomization of water droplets.

2. Lubrication:

As the compressed air is generated, the injected water serves as a lubricant for the internal components of the compressor. The water forms a thin film on the surfaces, reducing friction and wear between the moving parts. This lubrication helps to improve the efficiency and lifespan of the compressor.

3. Cooling:

The water injected into the compression chamber also acts as a cooling medium. As the air is compressed, heat is generated, and the injected water absorbs some of this heat. The water carries away the heat, preventing excessive temperature rise and maintaining optimal operating conditions for the compressor.

4. Separation and Filtration:

After serving its lubrication and cooling purposes, the water needs to be separated from the compressed air. The compressed air and water mixture pass through a separator or filtration system, which separates the water from the compressed air. This can involve mechanisms such as centrifugal force, gravity separation, or filtration media.

5. Water Treatment:

In water lubrication systems, proper water treatment is essential to maintain the quality and performance of the system. Water filtration and purification processes are employed to remove impurities, contaminants, and any solid particles present in the water. This ensures that the injected water is clean and free from any substances that could potentially harm the compressor or the downstream air system.

6. Recirculation or Discharge:

Depending on the specific design of the water lubrication system, the separated water can be recirculated back into the system for reuse or discharged from the compressor. Recirculation systems involve the treatment and filtration of the water before reintroducing it into the compression chamber. Discharge systems, on the other hand, may involve further treatment or disposal of the water in an environmentally responsible manner.

By utilizing a water lubrication system, air compressors can benefit from reduced oil consumption, improved air quality, and enhanced energy efficiency. These systems are commonly employed in industries where oil contamination must be avoided, such as food processing, pharmaceutical manufacturing, and electronics production.

China Professional Oac4000 High Quality Cheap Medical Oilless Portable 25lpm Silent Oil Free Air Compressor   with Best SalesChina Professional Oac4000 High Quality Cheap Medical Oilless Portable 25lpm Silent Oil Free Air Compressor   with Best Sales
editor by CX 2024-04-09